Optimization of Ultrasmall Superparamagnetic Iron Oxide (P904)-enhanced Magnetic Resonance Imaging of Lymph Nodes: Initial Experience in a MouseModel

Cited 2 time in webofscience Cited 2 time in scopus
1,088 Viewed 196 Downloaded
Title
Optimization of Ultrasmall Superparamagnetic Iron Oxide (P904)-enhanced Magnetic Resonance Imaging of Lymph Nodes: Initial Experience in a MouseModel
Author(s)
Yoo, RE; Cho, HR; Seung Hong Choi; Won, JK; Kim, JH; Sohn, CH
Subject
Animal study, lymph node metastasis, magnetic resonance imaging of lymph nodes, MRI, P904, ultra-small superparamagnetic iron oxide particle, USPIO
Publication Date
2014-10
Journal
ANTICANCER RESEARCH, v.34, no.10, pp.5389 - 5396
Publisher
INT INST ANTICANCER RESEARCH
Abstract
Background: P904 is a novel ultra-small superparamagnetic iron oxide (USPIO) contrast agent. This study was conducted to investigate the optimal dose of P904 for magnetic resonance imaging (MRI) of lymph nodes. Materials and Methods: T2*-weighted 3T MRI was performed in 14 normal mice before and 24 h after P904 injection at varying doses. Normalized signal intensity (nSI), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and contrast ratio (CR) were calculated to determine the optimal dose. MRI of the metastatic lymph node models (n=5) was acquired using the optimal dose and correlated with pathological results to calculate sensitivity and specificity. The mean SI ratio between pre- and postcontrast MRI was also calculated for each lymph node. Results: The mean nSI and SNR values on postcontrast images were significantly lower at 300 μmol Fe/kg than at 75 μmol Fe/kg (p<0.001). The mean CNR and CR values were significantly higher at 300 μmol Fe/kg than at the other two doses (p<0.05). At the optimal dose of 300 μmol Fe/kg, the mean SI ratio of benign lymph nodes was significantly lower than that of metastatic lymph nodes (p<0.001). The Az (areas under the receiver operating characteristic curves) value for diagnosing lymph node metastasis at the optimal dose was 0.97. Conclusion: The optimal dose for P904-enhanced MRI of the lymph nodes was 300 μmol Fe/kg, which could be used for the diagnosis of lymph node metastasis.
URI
https://pr.ibs.re.kr/handle/8788114/763
ISSN
0250-7005
Appears in Collections:
Center for Nanoparticle Research(나노입자 연구단) > 1. Journal Papers (저널논문)
Files in This Item:
Optimization of Ultrasmall Superparamagnetic.pdfDownload

qrcode

  • facebook

    twitter

  • Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse