BROWSE

Related Scientist

nanomat's photo.

nanomat
나노입자연구단
more info

ITEM VIEW & DOWNLOAD

Discovery of a solvent effect preventing quantitative profiling by matrix-assisted laser desorption/ionization and its treatment

Cited 4 time in webofscience Cited 4 time in scopus
1,313 Viewed 237 Downloaded
Title
Discovery of a solvent effect preventing quantitative profiling by matrix-assisted laser desorption/ionization and its treatment
Author(s)
Park K.M.; Moon J.H.; Kim J.H.; Song U.T.; Lee S.H.; Myung Soo Kim
Publication Date
2016-02
Journal
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, v.30, no.3, pp.386 - 392
Publisher
WILEY-BLACKWELL
Abstract
Rationale In analyte profiling by matrix-assisted laser desorption/ionization (MALDI), drawing a quantitative profile map is an outstanding problem. Recently, we developed a method to quantify an analyte by MALDI, which is needed to solve the problem. Another requirement for quantitative profiling is the quantitative sample-to-matrix analyte transfer, which is investigated in this work. Methods MALDI-time-of-flight (TOF) spectra were acquired for samples produced by two methods. In one, a sample solution containing a matrix and an analyte was loaded with a pipet and dried. In the other, a sample was prepared by a consecutive process, i.e., loading-drying of an analyte solution followed by that of a matrix solution. Two different micro-spotters were used in the second method. Various mixtures of organic solvents with water were used to prepare matrix solutions. Results The organic solvent, matrix, and analyte used in the study did not affect the analyte transfer efficiency, whereas it improved as the water content in the solvent increased. It also improved as the liquid droplet emitted by a micro-spotter got larger. Use of a more polar solvent or a larger droplet increases the contact time between a solution droplet and the sample surface, which seems to be responsible for the improvement in the transfer efficiency. Conclusions Sample-to-matrix analyte transfer occurred efficiently when polar solvents and/or large liquid droplets were used to produce solid samples for MALDI profiling with a micro-spotter. A long contact time between the sample surface and a matrix solution droplet is one of the requirements for quantitative profiling. Copyright © 2015 John Wiley & Sons, Ltd
URI
https://pr.ibs.re.kr/handle/8788114/2658
DOI
10.1002/rcm.7452
ISSN
0951-4198
Appears in Collections:
Center for Nanoparticle Research(나노입자 연구단) > 1. Journal Papers (저널논문)
Files in This Item:
Park_et_al-2016-Rapid_Communications_in_Mass_Spectrometry.pdfDownload

qrcode

  • facebook

    twitter

  • Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse