Urine-based liquid biopsy: non-invasive and sensitive AR-V7 detection in urinary EVs from patients with prostate cancer
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Hyun-Kyung Woo | - |
dc.contributor.author | Juhee Park | - |
dc.contributor.author | Ja Yoon Ku | - |
dc.contributor.author | Chan Ho Lee | - |
dc.contributor.author | Vijaya Sunkara | - |
dc.contributor.author | Hong Koo Ha | - |
dc.contributor.author | Yoon-Kyoung Cho | - |
dc.date.available | 2019-05-02T08:09:26Z | - |
dc.date.created | 2019-01-28 | - |
dc.date.issued | 2019-01 | - |
dc.identifier.issn | 1473-0197 | - |
dc.identifier.uri | https://pr.ibs.re.kr/handle/8788114/5734 | - |
dc.description.abstract | Androgen-receptor splice variant 7 (AR-V7) is associated with castration-resistant prostate cancer (CRPC) and resistance to anti-androgen therapy. Despite its clinical importance, the lack of efficient methods for AR-V7 analysis remains a challenge for broader use of this biomarker in routine clinical practice. Herein, we suggest a practical and non-invasive liquid biopsy method for analysis of AR-V7 in the RNA of urine-derived extracellular vesicles (EVs) without the need for blood withdrawal. Urine-derived EVs were isolated by a lab-on-a-disc integrated with six independent nanofiltration units (Exo-Hexa) allowing simultaneous processing of six individual samples. Rapid enrichment of EVs (<30 min) from each 4 mL urine sample was followed by mRNA extraction, and AR-V7 and androgen receptor full-length (AR-FL) mRNA levels in the urinary EVs were quantified by droplet digital polymerase chain reaction (ddPCR) as absolute concentrations (copies per mL). Higher AR-V7 and lower AR-FL expressions were detected in urine-derived EVs from 14 patients with CRPC than in those from 22 patients with hormone-sensitive prostate cancer. Additionally, we found that AR-V7 transcript levels and the AR-V7/AR-FL ratio in urinary EVs were higher in patients with advanced prostate cancer. This study is the first to report that RNA of urine-derived EVs is a reliable source for AR-V7 expression analysis. The proposed method for quantifying AR-V7 in urinary EVs prepared by a lab-on-a-disc is therefore a simple and promising approach to liquid biopsy with great potential for therapeutic impact on prostate cancer. © The Royal Society of Chemistry 2019 | - |
dc.description.uri | 1 | - |
dc.language | 영어 | - |
dc.publisher | The Royal Society of Chemistry | - |
dc.title | Urine-based liquid biopsy: non-invasive and sensitive AR-V7 detection in urinary EVs from patients with prostate cancer | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.identifier.wosid | 000453682500004 | - |
dc.identifier.scopusid | 2-s2.0-85058757894 | - |
dc.identifier.rimsid | 66736 | - |
dc.contributor.affiliatedAuthor | Hyun-Kyung Woo | - |
dc.contributor.affiliatedAuthor | Juhee Park | - |
dc.contributor.affiliatedAuthor | Vijaya Sunkara | - |
dc.contributor.affiliatedAuthor | Yoon-Kyoung Cho | - |
dc.identifier.doi | 10.1039/c8lc01185k | - |
dc.identifier.bibliographicCitation | LAB ON A CHIP, v.19, no.1, pp.87 - 97 | - |
dc.citation.title | LAB ON A CHIP | - |
dc.citation.volume | 19 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 87 | - |
dc.citation.endPage | 97 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |