BROWSE

Related Scientist

cslm's photo.

cslm
첨단연성물질연구단
more info

ITEM VIEW & DOWNLOAD

Urine-based liquid biopsy: non-invasive and sensitive AR-V7 detection in urinary EVs from patients with prostate cancer

DC Field Value Language
dc.contributor.authorHyun-Kyung Woo-
dc.contributor.authorJuhee Park-
dc.contributor.authorJa Yoon Ku-
dc.contributor.authorChan Ho Lee-
dc.contributor.authorVijaya Sunkara-
dc.contributor.authorHong Koo Ha-
dc.contributor.authorYoon-Kyoung Cho-
dc.date.available2019-05-02T08:09:26Z-
dc.date.created2019-01-28-
dc.date.issued2019-01-
dc.identifier.issn1473-0197-
dc.identifier.urihttps://pr.ibs.re.kr/handle/8788114/5734-
dc.description.abstractAndrogen-receptor splice variant 7 (AR-V7) is associated with castration-resistant prostate cancer (CRPC) and resistance to anti-androgen therapy. Despite its clinical importance, the lack of efficient methods for AR-V7 analysis remains a challenge for broader use of this biomarker in routine clinical practice. Herein, we suggest a practical and non-invasive liquid biopsy method for analysis of AR-V7 in the RNA of urine-derived extracellular vesicles (EVs) without the need for blood withdrawal. Urine-derived EVs were isolated by a lab-on-a-disc integrated with six independent nanofiltration units (Exo-Hexa) allowing simultaneous processing of six individual samples. Rapid enrichment of EVs (<30 min) from each 4 mL urine sample was followed by mRNA extraction, and AR-V7 and androgen receptor full-length (AR-FL) mRNA levels in the urinary EVs were quantified by droplet digital polymerase chain reaction (ddPCR) as absolute concentrations (copies per mL). Higher AR-V7 and lower AR-FL expressions were detected in urine-derived EVs from 14 patients with CRPC than in those from 22 patients with hormone-sensitive prostate cancer. Additionally, we found that AR-V7 transcript levels and the AR-V7/AR-FL ratio in urinary EVs were higher in patients with advanced prostate cancer. This study is the first to report that RNA of urine-derived EVs is a reliable source for AR-V7 expression analysis. The proposed method for quantifying AR-V7 in urinary EVs prepared by a lab-on-a-disc is therefore a simple and promising approach to liquid biopsy with great potential for therapeutic impact on prostate cancer. © The Royal Society of Chemistry 2019-
dc.description.uri1-
dc.language영어-
dc.publisherThe Royal Society of Chemistry-
dc.titleUrine-based liquid biopsy: non-invasive and sensitive AR-V7 detection in urinary EVs from patients with prostate cancer-
dc.typeArticle-
dc.type.rimsART-
dc.identifier.wosid000453682500004-
dc.identifier.scopusid2-s2.0-85058757894-
dc.identifier.rimsid66736-
dc.contributor.affiliatedAuthorHyun-Kyung Woo-
dc.contributor.affiliatedAuthorJuhee Park-
dc.contributor.affiliatedAuthorVijaya Sunkara-
dc.contributor.affiliatedAuthorYoon-Kyoung Cho-
dc.identifier.doi10.1039/c8lc01185k-
dc.identifier.bibliographicCitationLAB ON A CHIP, v.19, no.1, pp.87 - 97-
dc.citation.titleLAB ON A CHIP-
dc.citation.volume19-
dc.citation.number1-
dc.citation.startPage87-
dc.citation.endPage97-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Appears in Collections:
Center for Soft and Living Matter(첨단연성물질 연구단) > 1. Journal Papers (저널논문)
Files in This Item:
Urine-based liquid biopsy non-invasive and sensitive AR-V7 detection in urinary EVs from patients with prostate cancer.pdfDownload

qrcode

  • facebook

    twitter

  • Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse