BROWSE

Related Scientist

nanomat's photo.

nanomat
나노입자연구단
more info

ITEM VIEW & DOWNLOAD

Tracing the Origin of the Anomalous Matrix Suppression in Matrix‐assisted Laser Desorption Ionization and Extending the Linear Dynamic Range During Analyte Quantification

DC Field Value Language
dc.contributor.authorHyo In Song-
dc.contributor.authorTaeghwan Hyeon-
dc.contributor.authorMyung Soo Kim-
dc.contributor.authorJoo Yeon Oh-
dc.contributor.authorJeong Hee Moon-
dc.date.available2019-01-30T02:02:16Z-
dc.date.created2019-01-09-
dc.date.issued2018-02-
dc.identifier.issn0253-2964-
dc.identifier.urihttps://pr.ibs.re.kr/handle/8788114/5463-
dc.description.abstractIn the matrix-assisted laser desorption ionization-based quantification method developed in this laboratory, a linear calibration curve is constructed by plotting the analyte-to-matrix ion abundance ratio as a function of the analyte concentration. As the analyte concentration increases, however, the curve deviates from linearity. Previously, we observed that the occurrence of this deviation correlated with the decrease in the matrix ion signal, or matrix suppression. In this work, we found that saturation of the detector was one of the factors responsible for the above phenomena. As we decreased the detector gain, the upper limit of the linear dynamic range increased by as much as one order of magnitude. Even after a substantial decrease in the detector gain, however, the nonlinearity remained at a high analyte concentration, which we cannot account for at present. The method developed in this work can be useful for the quantitative imaging of analytes in heavily contaminated samples.© 2018 Korean Chemical Society, Seoul & Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim-
dc.description.uri1-
dc.language영어-
dc.publisherKOREAN CHEMICAL SOC-
dc.subjectMatrix-assisted laser desorption ionization quantification, Linear dynamic range, Matrix suppression,-
dc.subjectDetector saturation, Liquid matrix-
dc.titleTracing the Origin of the Anomalous Matrix Suppression in Matrix‐assisted Laser Desorption Ionization and Extending the Linear Dynamic Range During Analyte Quantification-
dc.typeArticle-
dc.type.rimsART-
dc.identifier.wosid000424333500010-
dc.identifier.scopusid2-s2.0-85040961695-
dc.identifier.rimsid66593-
dc.contributor.affiliatedAuthorHyo In Song-
dc.contributor.affiliatedAuthorTaeghwan Hyeon-
dc.contributor.affiliatedAuthorMyung Soo Kim-
dc.identifier.doi10.1002/bkcs.11368-
dc.identifier.bibliographicCitationBULLETIN OF THE KOREAN CHEMICAL SOCIETY, v.39, no.2, pp.207 - 212-
dc.citation.titleBULLETIN OF THE KOREAN CHEMICAL SOCIETY-
dc.citation.volume39-
dc.citation.number2-
dc.citation.startPage207-
dc.citation.endPage212-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Appears in Collections:
Center for Nanoparticle Research(나노입자 연구단) > 1. Journal Papers (저널논문)
Files in This Item:
5.tracing.pdfDownload

qrcode

  • facebook

    twitter

  • Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.