Use of commercial MALDI-TOFs for analyte quantification by a newly invented method
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park K.M. | - |
dc.contributor.author | Yoon S. | - |
dc.contributor.author | Moon J.H. | - |
dc.contributor.author | Lee S.H. | - |
dc.contributor.author | Myung Soo Kim | - |
dc.date.available | 2017-01-20T08:32:07Z | - |
dc.date.created | 2016-06-20 | - |
dc.date.issued | 2016-06 | - |
dc.identifier.issn | 0253-2964 | - |
dc.identifier.uri | https://pr.ibs.re.kr/handle/8788114/3294 | - |
dc.description.abstract | As part of the recently developed quantification method using matrix-assisted laser desorption ionization, matrix ion abundances are used to control the effective temperature, to construct a calibration curve, and to check the reliability of the quantification results. This method has not been used with commercial instruments owing to the difficulties in measuring the matrix ion abundances. In this work, we present a modification of each of the above guidelines to allow for quantification with commercial instruments. The modified method works with commercial instruments, which is partial proof for the validity of the method. © 2016 Korean Chemical Society & Wiley-VCH Verlag GmbH & Co. KGaA | - |
dc.description.uri | 1 | - |
dc.language | 영어 | - |
dc.publisher | KOREAN CHEMICAL SOC | - |
dc.subject | Commercial instrument | - |
dc.subject | Liquid matrix | - |
dc.subject | MALDI quantification | - |
dc.title | Use of commercial MALDI-TOFs for analyte quantification by a newly invented method | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.identifier.wosid | 000377648100020 | - |
dc.identifier.scopusid | 2-s2.0-84973380046 | - |
dc.identifier.rimsid | 55796 | - |
dc.date.tcdate | 2018-10-01 | - |
dc.contributor.affiliatedAuthor | Myung Soo Kim | - |
dc.identifier.doi | 10.1002/bkcs.10793 | - |
dc.identifier.bibliographicCitation | BULLETIN OF THE KOREAN CHEMICAL SOCIETY, v.37, no.6, pp.882 - 885 | - |
dc.citation.title | BULLETIN OF THE KOREAN CHEMICAL SOCIETY | - |
dc.citation.volume | 37 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 882 | - |
dc.citation.endPage | 885 | - |
dc.date.scptcdate | 2018-10-01 | - |
dc.description.wostc | 2 | - |
dc.description.scptc | 2 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordPlus | ASSISTED LASER-DESORPTION | - |
dc.subject.keywordPlus | DESORPTION/IONIZATION MASS-SPECTROMETRY | - |
dc.subject.keywordPlus | PEPTIDES | - |
dc.subject.keywordPlus | IONIZATION | - |
dc.subject.keywordPlus | REPRODUCIBILITY | - |
dc.subject.keywordPlus | MATRICES | - |
dc.subject.keywordPlus | SPECTRA | - |
dc.subject.keywordAuthor | MALDI quantification | - |
dc.subject.keywordAuthor | Commercial instrument | - |
dc.subject.keywordAuthor | Liquid matrix | - |