Investigations of Some Liquid Matrixes for Analyte Quantification by MALDI

Cited 8 time in webofscience Cited 9 time in scopus
1,090 Viewed 187 Downloaded
Title
Investigations of Some Liquid Matrixes for Analyte Quantification by MALDI
Author(s)
Moon, JH; Park, KM; Ahn, SH; Lee, SH; Myung Soo Kim
Subject
Liquid matrix, ; MALDI, ; MALDI quantification, ; 3AQ/CHCA, ; MALDI temperature, ; Matrix suppression, ; Reproducible MALDI
Publication Date
2015-10
Journal
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, v.26, no.10, pp.1657 - 1664
Publisher
SPRINGER
Abstract
Sample inhomogeneity is one of the obstacles preventing the generation of reproducible mass spectra by MALDI and to their use for the purpose of analyte quantification. As a potential solution to this problem, we investigated MALDI with some liquid matrixes prepared by nonstoichiometric mixing of acids and bases. Out of 27 combinations of acids and bases, liquid matrixes could be produced from seven. When the overall spectral features were considered, two liquid matrixes using alpha-cyano-4-hydroxycinnamic acid as the acid and 3-aminoquinoline and N,N-diethylaniline as bases were the best choices. In our previous study of MALDI with solid matrixes, we found that three requirements had to be met for the generation of reproducible spectra and for analyte quantification: (1) controlling the temperature by fixing the total ion count, (2) plotting the analyte-to-matrix ion ratio versus the analyte concentration as the calibration curve, and (3) keeping the matrix suppression below a critical value. We found that the same requirements had to be met in MALDI with liquid matrixes as well. In particular, although the liquid matrixes tested here were homogeneous, they failed to display spot-to-spot spectral reproducibility unless the first requirement above was met. We also found that analyte-derived ions could not be produced efficiently by MALDI with the above liquid matrixes unless the analyte was sufficiently basic. In this sense, MALDI processes with solid and liquid matrixes should be regarded as complementary techniques rather than as competing ones
URI
https://pr.ibs.re.kr/handle/8788114/1868
DOI
10.1007/s13361-015-1202-2
ISSN
1044-0305
Appears in Collections:
Center for Nanoparticle Research(나노입자 연구단) > 1. Journal Papers (저널논문)
Files in This Item:
Investigations of Some Liquid Matrixes for Analyte Quantification by MALDI.pdfDownload

qrcode

  • facebook

    twitter

  • Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse