Cerebral Blood Volume Analysis in Glioblastomas Using Dynamic Susceptibility Contrast-Enhanced Perfusion MRI: A Comparison of Manual and Semiautomatic Segmentation Methods

DC Field Value Language
dc.contributor.authorInseon Ryoo-
dc.contributor.authorSeung Hong Choi-
dc.contributor.authorJi-Hoon Kim-
dc.contributor.authorChul-Ho Sohn-
dc.contributor.authorSoo Chin Kim-
dc.contributor.authorHwa Seon Shin-
dc.contributor.authorJeong A. Yeom-
dc.contributor.authorSeung Chai Jung-
dc.contributor.authorA. Leum Lee-
dc.contributor.authorTae Jin Yun-
dc.contributor.authorPark, Chul-Kee-
dc.contributor.authorPark, Sung-Hye-
dc.date.available2015-04-20T06:49:29Z-
dc.date.created2014-08-11ko
dc.date.issued2013-08-
dc.identifier.issn1932-6203-
dc.identifier.urihttps://pr.ibs.re.kr/handle/8788114/1281-
dc.description.abstractPurpose: To compare the reproducibilities of manual and semiautomatic segmentation method for the measurement of normalized cerebral blood volume (nCBV) using dynamic susceptibility contrast-enhanced (DSC) perfusion MR imaging in glioblastomas. Materials and Methods: Twenty-two patients (11 male, 11 female; 27 tumors) with histologically confirmed glioblastoma (WHO grade IV) were examined with conventional MR imaging and DSC imaging at 3T before surgery or biopsy. Then nCBV (means and standard deviations) in each mass was measured using two DSC MR perfusion analysis methods including manual and semiautomatic segmentation method, in which contrast-enhanced (CE)-T1WI and T2WI were used as structural imaging. Intraobserver and interobserver reproducibility were assessed according to each perfusion analysis method or each structural imaging. Interclass correlation coefficient (ICC), Bland-Altman plot, and coefficient of variation (CV) were used to evaluate reproducibility. Results: Intraobserver reproducibilities on CE-T1WI and T2WI were ICC of 0.74–0.89 and CV of 20.39–36.83% in manual segmentation method, and ICC of 0.95–0.99 and CV of 8.53–16.19% in semiautomatic segmentation method, repectively. Interobserver reproducibilites on CE-T1WI and T2WI were ICC of 0.86–0.94 and CV of 19.67–35.15% in manual segmentation method, and ICC of 0.74–1.0 and CV of 5.48–49.38% in semiautomatic segmentation method, respectively. Bland-Altman plots showed a good correlation with ICC or CV in each method. The semiautomatic segmentation method showed higher intraobserver and interobserver reproducibilities at CE-T1WI-based study than other methods. Conclusion: The best reproducibility was found using the semiautomatic segmentation method based on CE-T1WI for structural imaging in the measurement of the nCBV of glioblastomas.-
dc.language영어-
dc.publisherPUBLIC LIBRARY SCIENCE-
dc.titleCerebral Blood Volume Analysis in Glioblastomas Using Dynamic Susceptibility Contrast-Enhanced Perfusion MRI: A Comparison of Manual and Semiautomatic Segmentation Methods-
dc.typeArticle-
dc.type.rimsART-
dc.identifier.wosid000323124000006-
dc.identifier.scopusid2-s2.0-84881322336-
dc.identifier.rimsid275ko
dc.date.tcdate2018-10-01-
dc.contributor.affiliatedAuthorInseon Ryoo-
dc.contributor.affiliatedAuthorSeung Hong Choi-
dc.contributor.affiliatedAuthorJi-Hoon Kim-
dc.contributor.affiliatedAuthorChul-Ho Sohn-
dc.contributor.affiliatedAuthorSoo Chin Kim-
dc.contributor.affiliatedAuthorHwa Seon Shin-
dc.contributor.affiliatedAuthorJeong A. Yeom-
dc.contributor.affiliatedAuthorSeung Chai Jung-
dc.contributor.affiliatedAuthorA. Leum Lee-
dc.contributor.affiliatedAuthorTae Jin Yun-
dc.identifier.doi10.1371/journal.pone.0069323-
dc.identifier.bibliographicCitationPLOS ONE, v.8, no.8, pp.e-69323-
dc.relation.isPartOfPLOS ONE-
dc.citation.titlePLOS ONE-
dc.citation.volume8-
dc.citation.number8-
dc.citation.startPagee-69323-
dc.date.scptcdate2018-10-01-
dc.description.wostc14-
dc.description.scptc16-
dc.description.journalClass1-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Appears in Collections:
Center for Nanoparticle Research(나노입자 연구단) > 1. Journal Papers (저널논문)
Files in This Item:
25. Cerebral Blood Volume Calculated by Dynamic Susceptibility.pdfDownload