BROWSE

Related Scientist

cn's photo.

cn
나노의학연구단
more info

ITEM VIEW & DOWNLOAD

Intraocular Pressure Monitoring following Islet Transplantation to the Anterior Chamber of the Eye

Cited 0 time in webofscience Cited 4 time in scopus
500 Viewed 136 Downloaded
Title
Intraocular Pressure Monitoring following Islet Transplantation to the Anterior Chamber of the Eye
Author(s)
Joohee Kim; Jaeyoon Kim; Minjae Ku; Eunkyung Cha; Seoyoung Ju; Won Yeong Park; Ki Hean Kim; Dai Woo Kim; Per-Olof Berggren; Jang-Ung Park
Publication Date
2020-03
Journal
NANO LETTERS, v.20, no.3, pp.1517 - 1525
Publisher
AMER CHEMICAL SOC
Abstract
© 2019 American Chemical Society.Intraocular islet transplantation was investigated as a new procedure to treat diabetes. The development of this procedure requires close monitoring of the function of both eye and islet graft. We developed a soft, smart contact lens to monitor the intraocular pressure and applied this for noninvasive monitoring in association with the intraocular islet transplantation in diabetes. A strain sensor inside the lens can detect detailed changes in intraocular pressure by focusing the strain only in the desired, selective area of the contact lens. In addition, this smart contact lens can transmit the real-time value of the intraocular pressure wirelessly using an antenna. The wireless measurement of intraocular pressure that was obtained using this contact lens had a high correlation with the intraocular pressure measured by a rebound tonometer, thereby proving the good accuracy of the contact lens sensor. In the initial period, a slight elevation of intraocular pressure was observed, but the pressure returned to normal in the initial period after the transplantation. This type of monitoring will provide important information on potential changes in the intraocular pressure associated with the transplantation procedure, and it enables appropriate clinical safety steps to be taken, if needed
URI
https://pr.ibs.re.kr/handle/8788114/7216
DOI
10.1021/acs.nanolett.9b03605
ISSN
1530-6984
Appears in Collections:
Center for Nanomedicine (나노의학 연구단) > 1. Journal Papers (저널논문)
Files in This Item:
Intraocular Pressure Monitoring Following Islet Transplantation to the Anterior Chamber of the Eye.pdfDownload

qrcode

  • facebook

    twitter

  • Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse