Dual Electrochemical Microsensor for Real-Time Simultaneous Monitoring of Nitric Oxide and Potassium Ion Changes in a Rat Brain during Spontaneous Neocortical Epileptic Seizure
Cited 12 time in
Cited 11 time in
938 Viewed
176 Downloaded
-
Title
- Dual Electrochemical Microsensor for Real-Time Simultaneous Monitoring of Nitric Oxide and Potassium Ion Changes in a Rat Brain during Spontaneous Neocortical Epileptic Seizure
-
Author(s)
- Jungmi Moon; Yejin Ha; Misun Kim; Jeongeun Sim; Youngmi Lee; Minah Suh
-
Publication Date
- 2016-09
-
Journal
- ANALYTICAL CHEMISTRY, v.88, no.18, pp.8942 - 8948
-
Publisher
- AMER CHEMICAL SOC
-
Abstract
- In this work, we developed a dual amperometric/potentiometric microsensor for sensing nitric oxide (NO) and potassium ion (K+). The dual NO/K+ sensor was prepared based on a dual recessed electrode possessing Pt (diameter, 50 μm) and Ag (diameter, 76.2 μm) microdisks. The Pt disk surface (WE1) was modified with electroplatinization and the following coating with fluorinated xerogel; and the Ag disk surface (WE2) was oxidized to AgCl on which K+ ion selective membrane was loaded subsequent to the silanization. WE1 and WE2 of a dual microsensor were used for amperometric sensing of NO (106 ± 28 pA μM-1, n = 10, at +0.85 V applied vs Ag/AgCl) and for potentiometric sensing of K+ (51.6 ± 1.9 mV pK-1, n = 10), respectively, with high sensitivity. In addition, the sensor showed good selectivity over common biological interferents, sufficiently fast response time and relevant stability (within 6 h in vivo experiment). The sensor had a small dimension (end plane diameter, 428 ± 97 μm, n = 20) and needle-like sharp geometry which allowed the sensor to be inserted in biological tissues. Taking advantage of this insertability, the sensor was applied for the simultaneous monitoring of NO and K+ changes in a living rat brain cortex at a depth of 1.19 ± 0.039 mm and near the spontaneous epileptic seizure focus. The seizures were induced with 4-aminopyridine injection onto the rat brain cortex. NO and K+ levels were dynamically changed in clear correlation with the electrophysiological recording of seizures. This indicates that the dual NO/K+ sensor's measurements well reflect membrane potential changes of neurons and associated cellular components of neurovascular coupling. The newly developed NO/K+ dual microsensor showed the feasibility of real-time fast monitoring of dynamic changes of closely linked NO and K+ in vivo. © 2016 American Chemical Society
-
URI
- https://pr.ibs.re.kr/handle/8788114/3128
-
DOI
- 10.1021/acs.analchem.6b02396
-
ISSN
- 0003-2700
-
Appears in Collections:
- Center for Neuroscience Imaging Research (뇌과학 이미징 연구단) > 1. Journal Papers (저널논문)
- Files in This Item:
-
cal Microsensor for Real-Time Simultaneous Monitoring of Nitric Oxide.pdfDownload
-
- Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.