BROWSE

Related Scientist

deuksoon,ahn's photo.

deuksoon,ahn
희귀핵연구단
more info

ITEM VIEW & DOWNLOAD

Performance of the prototype beam drift chamber for LAMPS at RAON with proton and 12C beams

DC Field Value Language
dc.contributor.authorKim, H.-
dc.contributor.authorBae, Y.-
dc.contributor.authorHeo, C.-
dc.contributor.authorSeo, J.-
dc.contributor.authorHwang, J.-
dc.contributor.authorMoon, D.H.-
dc.contributor.authorDeuk Soon Ahn-
dc.contributor.authorAhn, J.-
dc.contributor.authorBae, J.-
dc.contributor.authorBok, J.-
dc.contributor.authorCheon, Y.-
dc.contributor.authorChoi, S.-
dc.contributor.authorDo, S.-
dc.contributor.authorHong, B.-
dc.contributor.authorS.-W. Hong-
dc.contributor.authorJangyong HUH-
dc.contributor.authorHwang, S.-
dc.contributor.authorJang, Y.-
dc.contributor.authorKang, B.-
dc.contributor.authorKim, A.-
dc.contributor.authorKim, B.-
dc.contributor.authorKim, C.-
dc.contributor.authorKim, E.-J.-
dc.contributor.authorKim, G.-
dc.contributor.authorKim, G.-
dc.contributor.authorKim, J.-
dc.contributor.authorKim, J.-
dc.contributor.authorKim, S.-
dc.contributor.authorKim, Y.-
dc.contributor.authorKim, Y.-
dc.contributor.authorKim, Y.-
dc.contributor.authorY. Kim-
dc.contributor.authorKweon, M.-
dc.contributor.authorC. Lee-
dc.contributor.authorLee, H.-
dc.contributor.authorLee, H.-
dc.contributor.authorH. Lee-
dc.contributor.authorLee, J.-
dc.contributor.authorLee, J.-
dc.contributor.authorLee, J.-W.-
dc.contributor.authorJungwoo Lee-
dc.contributor.authorLee, S.-
dc.contributor.authorLee, S.-
dc.contributor.authorLee, S.-
dc.contributor.authorLim, S.-
dc.contributor.authorNam, S.-
dc.contributor.authorPark, J.-
dc.contributor.authorT. Shin-
dc.date.accessioned2025-01-14T09:00:03Z-
dc.date.available2025-01-14T09:00:03Z-
dc.date.created2024-12-16-
dc.date.issued2024-12-
dc.identifier.issn1748-0221-
dc.identifier.urihttps://pr.ibs.re.kr/handle/8788114/16187-
dc.description.abstractBeam Drift Chamber (BDC) is designed to reconstruct the trajectories of incident rare isotope beams provided by RAON (Rare isotope Accelerator complex for ON-line experiments) into the experimental target of LAMPS (Large Acceptance Multi-Purpose Spectrometer). To conduct the performance test of the BDC, the prototype BDC (pBDC) is manufactured and evaluated with the high energy ion beams from HIMAC (Heavy Ion Medical Accelerator in Chiba) facility in Japan. Two kinds of ion beams, 100 MeV proton, and 200 MeV/u 12C, have been utilized for this evaluation, and the track reconstruction efficiency and position resolution have been measured as the function of applied high voltage. This paper introduces the construction details and presents the track reconstruction efficiency and position resolution of pBDC. © 2024 IOP Publishing Ltd and Sissa Medialab. All rights, including for text and data mining, AI training, and similar technologies, are reserved.-
dc.language영어-
dc.publisherInstitute of Physics-
dc.titlePerformance of the prototype beam drift chamber for LAMPS at RAON with proton and 12C beams-
dc.typeArticle-
dc.type.rimsART-
dc.identifier.scopusid2-s2.0-85211344279-
dc.identifier.rimsid84720-
dc.contributor.affiliatedAuthorDeuk Soon Ahn-
dc.contributor.affiliatedAuthorS.-W. Hong-
dc.contributor.affiliatedAuthorJangyong HUH-
dc.contributor.affiliatedAuthorY. Kim-
dc.contributor.affiliatedAuthorC. Lee-
dc.contributor.affiliatedAuthorH. Lee-
dc.contributor.affiliatedAuthorJungwoo Lee-
dc.contributor.affiliatedAuthorT. Shin-
dc.identifier.doi10.1088/1748-0221/19/12/P12008-
dc.identifier.bibliographicCitationJournal of Instrumentation, v.19, no.12-
dc.relation.isPartOfJournal of Instrumentation-
dc.citation.titleJournal of Instrumentation-
dc.citation.volume19-
dc.citation.number12-
dc.description.journalClass1-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordAuthorGaseous detectors-
dc.subject.keywordAuthorParticle tracking detectors (Gaseous detectors)-
dc.subject.keywordAuthorWire chambers (MWPC, Thin-gap chambers, drift chambers, drift tubes, proportional chambers etc)-
dc.subject.keywordAuthorBeam-line instrumentation (beam position and profile monitors, beam-intensity monitors, bunch length monitors)-
Appears in Collections:
Center for Exotic Nuclear Studies(희귀 핵 연구단) > 1. Journal Papers (저널논문)
Files in This Item:
There are no files associated with this item.

qrcode

  • facebook

    twitter

  • Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse