A position-sensitive large-area microchannel plate detector with digital data-acquisition system for studies of exotic nuclei
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Zeren Korkulu | - |
dc.contributor.author | Laszlo Stuhl | - |
dc.contributor.author | Naimi, S. | - |
dc.contributor.author | Dombrádi, Zs. | - |
dc.contributor.author | Kevin Insik Hahn | - |
dc.contributor.author | Moon, J.Y. | - |
dc.contributor.author | Deuk Soon Ahn | - |
dc.contributor.author | Halasz, Z. | - |
dc.contributor.author | Hudson-Chang, G. | - |
dc.date.accessioned | 2023-06-28T22:00:14Z | - |
dc.date.available | 2023-06-28T22:00:14Z | - |
dc.date.created | 2023-06-09 | - |
dc.date.issued | 2023-08 | - |
dc.identifier.issn | 0168-583X | - |
dc.identifier.uri | https://pr.ibs.re.kr/handle/8788114/13512 | - |
dc.description.abstract | Development of a position-sensitive large-area microchannel plate (MCP) detector based detection system is reported. Two MCPs with 120 mm active diameter, mounted in chevron configuration, with delay-line anode are read out by a digital data-acquisition system consists of fast-timing amplifier unit and CAEN v1751 waveform digitizer. Details of the digital pulse processing, programmed triggering and calibration setup are described. The obtained position resolution was studied using α-particles, the best resolutions on X and Y axes are 460 ± 1μm and 579 ± 1μm in FWHM, respectively. © 2023 Elsevier B.V. | - |
dc.language | 영어 | - |
dc.publisher | Elsevier B.V. | - |
dc.title | A position-sensitive large-area microchannel plate detector with digital data-acquisition system for studies of exotic nuclei | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.identifier.wosid | 001058511600001 | - |
dc.identifier.scopusid | 2-s2.0-85160202568 | - |
dc.identifier.rimsid | 80898 | - |
dc.contributor.affiliatedAuthor | Zeren Korkulu | - |
dc.contributor.affiliatedAuthor | Laszlo Stuhl | - |
dc.contributor.affiliatedAuthor | Kevin Insik Hahn | - |
dc.contributor.affiliatedAuthor | Deuk Soon Ahn | - |
dc.identifier.doi | 10.1016/j.nimb.2023.05.032 | - |
dc.identifier.bibliographicCitation | Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, v.541, pp.232 - 235 | - |
dc.relation.isPartOf | Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms | - |
dc.citation.title | Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms | - |
dc.citation.volume | 541 | - |
dc.citation.startPage | 232 | - |
dc.citation.endPage | 235 | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalResearchArea | Nuclear Science & Technology | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
dc.relation.journalWebOfScienceCategory | Physics, Atomic, Molecular & Chemical | - |
dc.relation.journalWebOfScienceCategory | Physics, Nuclear | - |
dc.subject.keywordAuthor | Delay-line anode | - |
dc.subject.keywordAuthor | Digital data-acquisition | - |
dc.subject.keywordAuthor | Digital pulse processing | - |
dc.subject.keywordAuthor | Microchannel plate detectors | - |
dc.subject.keywordAuthor | Position resolution | - |