BROWSE

Related Scientist

cnir's photo.

cnir
뇌과학이미징연구단
more info

ITEM VIEW & DOWNLOAD

Baseline Correction of the Human H-1 MRS(I) Spectrum Using T-2* Selective Differential Operators in the Frequency Domain

Cited 0 time in webofscience Cited 0 time in scopus
178 Viewed 0 Downloaded
Title
Baseline Correction of the Human H-1 MRS(I) Spectrum Using T-2* Selective Differential Operators in the Frequency Domain
Author(s)
Sang-Han Choi; Ryu, Yeun-Chul; Chung, Jun-Young
Publication Date
2022-12
Journal
METABOLITES, v.12, no.12
Publisher
MDPI
Abstract
The baseline distortion caused by water and fat signals is a crucial issue in the H-1 MRS(I) study of the human brain. This paper suggests an effective and reliable preprocessing technique to calibrate the baseline distortion caused by the water and fat signals exhibited in the MRS spectral signal. For the preprocessing, we designed a T-2* (or linewidth within the spectral signal) selective filter for the MRS(I) data based on differential filtering within the frequency domain. The number and types for the differential filtering were determined by comparing the T-2* selectivity profile of each differential operator with the T-2* profile of the metabolites to be suppressed within the MRS(I) data. In the performance evaluation of the proposed differential filtering, the simulation data for MRS spectral signals were used. Furthermore, the spectral signal of the human H-1 MRSI data obtained by 2D free induction decay chemical shift imaging with a typical water suppression technique was also used in the performance evaluation. The absolute values of the average of the filtered dataset were quantitatively analyzed using the LCModel software. With the suggested T-2* selective (not frequency selective) filtering technique, in the simulated MRS data, we removed the metabolites from the simulated MRS(I) spectral signal baseline distorted by the water and fat signal observed in the most frequency band. Moreover, in the obtained MRSI data, the quantitative analysis results for the metabolites of interest showed notable improvement in the uncertainty estimation accuracy, the CRLB (Cramer-Rao Lower Bound) levels.
URI
https://pr.ibs.re.kr/handle/8788114/12467
DOI
10.3390/metabo12121257
ISSN
2218-1989
Appears in Collections:
Center for Neuroscience Imaging Research (뇌과학 이미징 연구단) > 1. Journal Papers (저널논문)
Files in This Item:
There are no files associated with this item.

qrcode

  • facebook

    twitter

  • Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse