BROWSE

Related Scientist

sanggoon,kim's photo.

sanggoon,kim
지하실험연구단
more info

ITEM VIEW & DOWNLOAD

Low temperature property study of MMCs used for neutrinoless double beta decay

Cited 0 time in webofscience Cited 0 time in scopus
444 Viewed 0 Downloaded
Title
Low temperature property study of MMCs used for neutrinoless double beta decay
Author(s)
Sang Goon Kim; Jin A Jeon; Han Beom Kim; Hyelim Kim; So Ra Kim; Yong Hamb Kim; Dohyung Kwon; Min Kyu Lee; Yong Chang Lee; Kyungrae Woo
Publication Date
2021-08
Journal
IEEE Transactions on Applied Superconductivity, v.31, no.5
Publisher
Institute of Electrical and Electronics Engineers
Abstract
© 2021 IEEE. Personal use is permitted, but republication/redistribution requires IEEE permission. We present a comparison of the two types of metallic magnetic calorimeters (MMCs) developed for a large-scale neutrinoless double beta decay (0νββ) search experiment. As high resolution micro-calorimeters,MMCsemploy micro-fabricated superconducting circuits to measure the changes in magnetization of a paramagnetic sensor material. We constructed two alpha spectrometers with two MMC sensors made of Au:Er and Ag:Er (i.e., gold and silver alloys with small concentrations of Er). A piece of gold foil with a heat capacity comparable to that of 350 g CaMoO4 crystal near 10 mK was used as the absorber for each alpha spectrometer. These detector setups allowed us to investigate the temperature dependence of magnetization for the different sensor materials over a wide temperature range with various amounts of field current. The magnetizationmeasurements for both the Au:Er and Ag:Er sensors were in good agreement with calculations for field currents of up to 100 mA. Moreover, the measured and estimated pulse heights of alpha events agreed with each other, and were compared between the different sensor materials.We discuss howthe excess heat capacity fromthe nuclear spins in Au:Er influences the pulse size and shape in calorimetric detection. Moreover, we describe the benefit of using Ag:Er sensors in thermal calorimeters with large crystal absorbers in a 0νββ search experiment.
URI
https://pr.ibs.re.kr/handle/8788114/11755
DOI
10.1109/TASC.2021.3066179
ISSN
1051-8223
Appears in Collections:
Center for Underground Physics(지하실험 연구단) > 1. Journal Papers (저널논문)
Files in This Item:
There are no files associated with this item.

qrcode

  • facebook

    twitter

  • Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse