Sagnac interferometer for time-resolved magneto-optical measurements
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Hyeokjun Heo | - |
dc.contributor.author | Kim, Taeho | - |
dc.contributor.author | Yungi Jeong | - |
dc.contributor.author | Hangyeol Park | - |
dc.contributor.author | Joonho Jang | - |
dc.date.accessioned | 2022-03-04T09:37:50Z | - |
dc.date.available | 2022-03-04T09:37:50Z | - |
dc.date.created | 2022-02-08 | - |
dc.date.issued | 2022-01 | - |
dc.identifier.issn | 0034-6748 | - |
dc.identifier.uri | https://pr.ibs.re.kr/handle/8788114/11207 | - |
dc.description.abstract | © 2022 Author(s).We introduce a time-resolved magneto-optical measurement technique based on a zero-area Sagnac interferometer. By replacing a continuous wave light source to a pulsed one, temporal resolution of hundreds of picoseconds is achieved. Because two lights passing through a Sagnac loop always travel the same optical path length, the interference from the phase modulation and Kerr rotation occurs in a pulse mode. For illustration of the apparatus, we present ferromagnetic resonance of a Permalloy film caused by a magnetic field pump. The instrument still possesses the favorable properties of a Sagnac interferometer, such as rejection of all the reciprocal effects, and shows 1μrad/Hz sensitivity at a 3 μW optical power in the pulse mode. | - |
dc.language | 영어 | - |
dc.publisher | American Institute of Physics Inc. | - |
dc.title | Sagnac interferometer for time-resolved magneto-optical measurements | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.identifier.wosid | 000745643000004 | - |
dc.identifier.scopusid | 2-s2.0-85122978375 | - |
dc.identifier.rimsid | 77194 | - |
dc.contributor.affiliatedAuthor | Hyeokjun Heo | - |
dc.contributor.affiliatedAuthor | Yungi Jeong | - |
dc.contributor.affiliatedAuthor | Hangyeol Park | - |
dc.contributor.affiliatedAuthor | Joonho Jang | - |
dc.identifier.doi | 10.1063/5.0073908 | - |
dc.identifier.bibliographicCitation | Review of Scientific Instruments, v.93, no.1 | - |
dc.relation.isPartOf | Review of Scientific Instruments | - |
dc.citation.title | Review of Scientific Instruments | - |
dc.citation.volume | 93 | - |
dc.citation.number | 1 | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.subject.keywordPlus | SUPERCONDUCTOR | - |
dc.subject.keywordPlus | YBA2CU3O7 | - |
dc.subject.keywordPlus | ORDER | - |