A multi-inversion multi-echo spin and gradient echo echo planar imaging sequence with low image distortion for rapid quantitative parameter mapping and synthetic image contrasts
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Manhard, Mary Kate | - |
dc.contributor.author | Stockmann, Jason | - |
dc.contributor.author | Liao, Congyu | - |
dc.contributor.author | Park, Daniel | - |
dc.contributor.author | Sohyun Han | - |
dc.contributor.author | Fair, Merlin | - |
dc.contributor.author | van den Boomen, Maaike | - |
dc.contributor.author | Polimeni, Jon | - |
dc.contributor.author | Bilgic, Berkin | - |
dc.contributor.author | Setsompop, Kawin | - |
dc.date.accessioned | 2021-04-29T01:50:02Z | - |
dc.date.accessioned | 2021-04-29T01:50:02Z | - |
dc.date.available | 2021-04-29T01:50:02Z | - |
dc.date.available | 2021-04-29T01:50:02Z | - |
dc.date.created | 2021-04-26 | - |
dc.date.issued | 2021-08 | - |
dc.identifier.issn | 0740-3194 | - |
dc.identifier.uri | https://pr.ibs.re.kr/handle/8788114/9559 | - |
dc.description.abstract | © 2021 International Society for Magnetic Resonance in MedicinePurpose: Brain imaging exams typically take 10-20 min and involve multiple sequential acquisitions. A low-distortion whole-brain echo planar imaging (EPI)-based approach was developed to efficiently encode multiple contrasts in one acquisition, allowing for calculation of quantitative parameter maps and synthetic contrast-weighted images. Methods: Inversion prepared spin- and gradient-echo EPI was developed with slice-order shuffling across measurements for efficient acquisition with T1, T2, and (Formula presented.) weighting. A dictionary-matching approach was used to fit the images to quantitative parameter maps, which in turn were used to create synthetic weighted images with typical clinical contrasts. Dynamic slice-optimized multi-coil shimming with a B0 shim array was used to reduce B0 inhomogeneity and, therefore, image distortion by >50%. Multi-shot EPI was also implemented to minimize distortion and blurring while enabling high in-plane resolution. A low-rank reconstruction approach was used to mitigate errors from shot-to-shot phase variation. Results: The slice-optimized shimming approach was combined with in-plane parallel-imaging acceleration of 4× to enable single-shot EPI with more than eight-fold distortion reduction. The proposed sequence efficiently obtained 40 contrasts across the whole-brain in just over 1 min at 1.2 × 1.2 × 3 mm resolution. The multi-shot variant of the sequence achieved higher in-plane resolution of 1 × 1 × 4 mm with good image quality in 4 min. Derived quantitative maps showed comparable values to conventional mapping methods. Conclusion: The approach allows fast whole-brain imaging with quantitative parameter maps and synthetic weighted contrasts. The slice-optimized multi-coil shimming and multi-shot reconstruction approaches result in minimal EPI distortion, giving the sequence the potential to be used in rapid screening applications. | - |
dc.language | 영어 | - |
dc.publisher | John Wiley and Sons Inc | - |
dc.title | A multi-inversion multi-echo spin and gradient echo echo planar imaging sequence with low image distortion for rapid quantitative parameter mapping and synthetic image contrasts | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.identifier.wosid | 000632464500001 | - |
dc.identifier.scopusid | 2-s2.0-85103185599 | - |
dc.identifier.rimsid | 75470 | - |
dc.contributor.affiliatedAuthor | Sohyun Han | - |
dc.identifier.doi | 10.1002/mrm.28761 | - |
dc.identifier.bibliographicCitation | Magnetic Resonance in Medicine, v.86, no.2, pp.866 - 880 | - |
dc.relation.isPartOf | Magnetic Resonance in Medicine | - |
dc.citation.title | Magnetic Resonance in Medicine | - |
dc.citation.volume | 86 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 866 | - |
dc.citation.endPage | 880 | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | LOW-RANK | - |
dc.subject.keywordPlus | MAGNETIZATION-TRANSFER | - |
dc.subject.keywordPlus | HUMAN BRAIN | - |
dc.subject.keywordPlus | T-1 | - |
dc.subject.keywordPlus | MRI | - |
dc.subject.keywordPlus | EPI | - |
dc.subject.keywordPlus | RECONSTRUCTION | - |
dc.subject.keywordPlus | MULTICONTRAST | - |
dc.subject.keywordPlus | RELAXATION | - |
dc.subject.keywordPlus | TISSUE | - |
dc.subject.keywordAuthor | multi-shot acquisitions | - |
dc.subject.keywordAuthor | quantitative mapping | - |
dc.subject.keywordAuthor | synthetic imaging | - |
dc.subject.keywordAuthor | low distortion EPI | - |