Simulation Study for the Half-Life Measurement of Ta-180m Using HPGe Detectors
DC Field | Value | Language |
---|---|---|
dc.contributor.author | G. W. Kim | - |
dc.contributor.author | S. Y. Park | - |
dc.contributor.author | I. S. Hahn | - |
dc.contributor.author | Yeongduk Kim | - |
dc.contributor.author | Moo Hyun Lee | - |
dc.contributor.author | Leonard Douglas | - |
dc.contributor.author | Eun Kyoung Lee | - |
dc.contributor.author | Woon Gu Kang | - |
dc.contributor.author | Sala Elena | - |
dc.contributor.author | V. Kazalov | - |
dc.date.available | 2019-11-28T06:13:51Z | - |
dc.date.created | 2019-08-20 | - |
dc.date.issued | 2019-07 | - |
dc.identifier.issn | 0374-4884 | - |
dc.identifier.uri | https://pr.ibs.re.kr/handle/8788114/6586 | - |
dc.description.abstract | Ta-180m, which is the second excited state of Ta-180 at E-x = 77 keV, is naturally occurring and is the only known stable isomer. The half-life of Ta-180m is considered to be an important parameter for nuclear synthesis models for heavy elements. However, the decay of Ta-180m has never been observed even though several groups tried to measure it. We will search for gamma transitions from Ta-180m decays in a tantalum sample by using an array of fourteen HPGe detectors recently installed in an underground laboratory at Yangyang, Korea. In preparation for the measurement, Monte-Carlo simulation studies were conducted to optimize the tantalum sample configuration. Based on the simulation study, we decided on a configuration composed of a 2 mm thick disk with diameter of 200 mm and six 2 mm thick rectangular plates with dimension of 158 x 195 mm(2). The finalized tantalum sample configuration gives 2.0 and 7.5 coincidence events per year for the EC and the beta-decay of Ta-180m, respectively. In this study, we used T-1/2 =2.0 x 10(17) years and T-1/2 = 5.8 x 10(16) years for the EC and beta-decay which are the present best lower-limits as reported by B. Lehnert et al. c 2019 The Korean Physical Society | - |
dc.description.uri | 1 | - |
dc.language | 영어 | - |
dc.publisher | KOREAN PHYSICAL SOC | - |
dc.subject | HPGe detector | - |
dc.subject | Monte-Carlo simulation | - |
dc.subject | Beta decay | - |
dc.subject | Ta-180m | - |
dc.title | Simulation Study for the Half-Life Measurement of Ta-180m Using HPGe Detectors | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.identifier.wosid | 000475631400006 | - |
dc.identifier.scopusid | 2-s2.0-85068784648 | - |
dc.identifier.rimsid | 69504 | - |
dc.contributor.affiliatedAuthor | Yeongduk Kim | - |
dc.contributor.affiliatedAuthor | Moo Hyun Lee | - |
dc.contributor.affiliatedAuthor | Leonard Douglas | - |
dc.contributor.affiliatedAuthor | Eun Kyoung Lee | - |
dc.contributor.affiliatedAuthor | Woon Gu Kang | - |
dc.contributor.affiliatedAuthor | Sala Elena | - |
dc.identifier.doi | 10.3938/jkps.75.32 | - |
dc.identifier.bibliographicCitation | JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.75, no.1, pp.32 - 39 | - |
dc.citation.title | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
dc.citation.volume | 75 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 32 | - |
dc.citation.endPage | 39 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordPlus | NUCLEOSYNTHESIS | - |
dc.subject.keywordPlus | RADIOACTIVITY | - |
dc.subject.keywordPlus | SEARCH | - |
dc.subject.keywordAuthor | HPGe detector | - |
dc.subject.keywordAuthor | Monte-Carlo simulation | - |
dc.subject.keywordAuthor | Beta decay | - |
dc.subject.keywordAuthor | Ta-180m | - |