F-18 Half-life measurement using 2-gamma coincidence method

DC Field Value Language
dc.contributor.authorKang, YS-
dc.contributor.authorAhn, JK-
dc.contributor.authorKim, Sung Hyun-
dc.contributor.authorByun, JI-
dc.contributor.authorHan, JB-
dc.contributor.authorLee, KB-
dc.date.available2018-07-18T02:09:48Z-
dc.date.created2018-03-15-
dc.date.issued2015-11-
dc.identifier.issn0168-9002-
dc.identifier.urihttps://pr.ibs.re.kr/handle/8788114/4847-
dc.description.abstractThe accuracy of the half-life measurement of short-lived radioisotopes such as positron-emitting F-18 (tau(1/2) approximate to 100 min) is limited mainly by inaccuracies in the detector counting statistics. Gamma-ray measurement with a high-activity F-18 source requires counting-loss corrections to compensate for random summing effects and the detector's dead time. In this study, we measure the half-life of F-18 with two 511-keV gamma-rays using two high-purity germanium (HPGe) detectors. The counting-loss corrections are performed via two approaches to address the problems of random coincidence summing and dead time: a half-life measurement with a Na-22 source and a Geant4 simulation of the detector response. Variations in the full-width at half maximum (FWHM) of the 511-keV peak are found to show good correlation with the random summing effect. The half-life of F-18 is estimated as 109.73 +/- 0.14 min. (C) 2015 Elsevier B.V. All rights reserved-
dc.description.uri1-
dc.language영어-
dc.publisherELSEVIER SCIENCE BV-
dc.subjectCoincidence measurement-
dc.subjectDead time correction-
dc.subjectHPGe detector-
dc.subjectF-18-
dc.titleF-18 Half-life measurement using 2-gamma coincidence method-
dc.typeArticle-
dc.type.rimsART-
dc.identifier.wosid000362282200002-
dc.identifier.scopusid2-s2.0-84941037019-
dc.identifier.rimsid62538ko
dc.date.tcdate2018-10-01-
dc.contributor.affiliatedAuthorKim, Sung Hyun-
dc.identifier.doi10.1016/j.nima.2015.08.025-
dc.identifier.bibliographicCitationNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, v.801, pp.7 - 10-
dc.citation.titleNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT-
dc.citation.volume801-
dc.citation.startPage7-
dc.citation.endPage10-
dc.date.scptcdate2018-10-01-
dc.description.scptc0-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordPlusPILE-UP CORRECTIONS-
dc.subject.keywordPlusDEAD-TIME-
dc.subject.keywordPlusSTANDARDIZATION-
dc.subject.keywordPlusSPECTROMETRY-
dc.subject.keywordPlusREJECTION-
dc.subject.keywordAuthorCoincidence measurement-
dc.subject.keywordAuthorDead time correction-
dc.subject.keywordAuthorHPGe detector-
dc.subject.keywordAuthorF-18-
Appears in Collections:
Center for Underground Physics(지하실험 연구단) > 1. Journal Papers (저널논문)
Files in This Item:
1-s2.0-S0168900215009596-main.pdfDownload

qrcode

  • facebook

    twitter

  • Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse