Study of a generalized birks formula for the scintillation response of a CaMoO4 crystal
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee J.Y. | - |
dc.contributor.author | Kim H.J. | - |
dc.contributor.author | Kang S.J. | - |
dc.contributor.author | Moo Hyun Lee | - |
dc.date.available | 2018-07-18T02:07:53Z | - |
dc.date.created | 2018-01-23 | - |
dc.date.issued | 2017-12 | - |
dc.identifier.issn | 0374-4884 | - |
dc.identifier.uri | https://pr.ibs.re.kr/handle/8788114/4747 | - |
dc.description.abstract | We have investigated the scintillation characteristics of CaMoO4 (CMO) crystals by using a gamma source and various internal alpha sources. A 137Cs source with 662-keV gamma-rays was used for the gamma-quanta light yield calibration. Internal radioactive contaminations provided alpha particles with different energies from 5.41 to 7.88 MeV. We developed a C++ program based on the ROOT package for the fitting of parameters in a generalized Birks semi-empirical formula by combining the experimental and the simulation data. Results for the fitted Birks parameters are kb1 = 3.3 × 10 −3 (g/MeVcm2) for the 1st parameter and kb2 = 7.9 × 10 −5 (g/MeVcm2)2 for the 2nd parameter. The χ2/n.d.f. (Number of Degree of Freedom) is calculated as 0.1/4. We were able to estimate the 238U and 234U contaminations in a CMO crystal by using the generalized Birks semi-empirical formula. © 2017, The Korean Physical Society | - |
dc.description.uri | 1 | - |
dc.language | 영어 | - |
dc.publisher | KOREAN PHYSICAL SOC | - |
dc.subject | Birks parameter | - |
dc.subject | CMO crystal | - |
dc.subject | Scintillation detector | - |
dc.subject | Scintillation response | - |
dc.title | Study of a generalized birks formula for the scintillation response of a CaMoO4 crystal | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.identifier.wosid | 000419003800011 | - |
dc.identifier.scopusid | 2-s2.0-85039450563 | - |
dc.identifier.rimsid | 62055 | - |
dc.date.tcdate | 2018-10-01 | - |
dc.contributor.affiliatedAuthor | Moo Hyun Lee | - |
dc.identifier.doi | 10.3938/jkps.71.928 | - |
dc.identifier.bibliographicCitation | JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.71, no.12, pp.928 - 933 | - |
dc.citation.title | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
dc.citation.volume | 71 | - |
dc.citation.number | 12 | - |
dc.citation.startPage | 928 | - |
dc.citation.endPage | 933 | - |
dc.date.scptcdate | 2018-10-01 | - |
dc.description.wostc | 1 | - |
dc.description.scptc | 1 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Birks parameter | - |
dc.subject.keywordAuthor | CMO crystal | - |
dc.subject.keywordAuthor | Scintillation detector | - |
dc.subject.keywordAuthor | Scintillation response | - |