BROWSE

ITEM VIEW & DOWNLOAD

Measurement of the drift velocity and transverse diffusion of electrons in liquid xenon with the EXO-200 detector

Cited 16 time in webofscience Cited 17 time in scopus
1,523 Viewed 621 Downloaded
Title
Measurement of the drift velocity and transverse diffusion of electrons in liquid xenon with the EXO-200 detector
Author(s)
J. B. Albert; P. S. Barbeau; D. Beck; V. Belov; M. Breidenbach; T. Brunner; A. Burenkov; G. F. Cao; W. R. Cen; C. Chambers; B. Cleveland; M. Coon; A. Craycraft; T. Daniels; M. Danilov; S. J. Daugherty; J. Daughhetee; J. Davis; S. Delaquis; A. Der Mesrobian-Kabakian; R. DeVoe; T. Didberidze; J. Dilling; A. Dolgolenko; M. J. Dolinski; M. Dunford; W. Fairbank Jr.; J. Farine; S. Feyzbakhsh; P. Fierlinger; D. Fudenberg; R. Gornea; K. Graham; G. Gratta; C. Hall; M. Hughes; M. J. Jewell; A. Johnson; T. N. Johnson; S. Johnston; A. Karelin; L. J. Kaufman; R. Killick; T. Koffas; S. Kravitz; R. Kr¨ucken; A. Kuchenkov; K. S. Kumar; Y. Lan; D.S. Leonard; C. Licciardi; Y. H. Lin; R. MacLellan; M. G. Marino; B. Mong; D. Moore; O. Njoya; R. Nelson; A. Odian; I. Ostrovskiy; A. Piepke; A. Pocar; C. Y. Prescott; F. Reti`ere; P. C. Rowson; J. J. Russell; A. Schubert; D. Sinclair; E. Smith; V. Stekhanov; M. Tarka; T. Tolba; R. Tsang; K. Twelker; J.-L. Vuilleumier; A. Waite; J. Walton; T. Walton; M. Weber; L. J. Wen; U. Wichoski; J. Wood; L. Yang; Y.-R. Yen; O. Ya. Zeldovich; J. Zettlemoyer
Publication Date
2017-02
Journal
Physical Review c, v.95, no.2, pp.025502
Publisher
AMER PHYSICAL SOC
Abstract
The EXO-200 Collaboration is searching for neutrinoless double beta decay using a liquid xenon (LXe) time projection chamber. This measurement relies on modeling the transport of charge deposits produced by interactions in the LXe to allow discrimination between signal and background events. Here we present measurements of the transverse diffusion constant and drift velocity of electrons at drift fields between 20 V/cm and 615 V/cm using EXO-200 data. At the operating field of 380 V/cm EXO-200 measures a drift velocity of 1.705(-0.010)(+0.014) mm/mu s and a transverse diffusion coefficient of 55 +/- 4 cm(2)/s. © 2017 American Physical Society
URI
https://pr.ibs.re.kr/handle/8788114/4250
DOI
10.1103/PhysRevC.95.025502
ISSN
2469-9985
Appears in Collections:
Center for Underground Physics(지하실험 연구단) > 1. Journal Papers (저널논문)
Files in This Item:
PhysRevC.95.pdfDownload