BROWSE

Related Scientist

cnir's photo.

cnir
뇌과학이미징연구단
more info

ITEM VIEW & DOWNLOAD

Nuclear paramagnetism-induced MR frequency shift and its implications for MR-based magnetic susceptibility measurement

DC Field Value Language
dc.contributor.authorJinil Park-
dc.contributor.authorJeongtaek Lee-
dc.contributor.authorJang-Yeon Park-
dc.contributor.authorSeung-Kyun Lee-
dc.date.available2017-09-05T05:33:27Z-
dc.date.created2017-02-24-
dc.date.issued2017-02-
dc.identifier.issn0740-3194-
dc.identifier.urihttps://pr.ibs.re.kr/handle/8788114/3768-
dc.description.abstractPurpose: To investigate the 1H spin contribution (0.004 parts per million (ppm)) to the water magnetic susceptibility and discuss its implications for high-precision phase mapping and tissue susceptibility measurement. Methods: Free induction decay (FID) signals were acquired at 3 Tesla (T) and 9.4T from thin square phantoms at a range of tip angles. The FID frequency shift was examined at a high resolution (< 0.01 Hz) for different phantom orientations relative to the main magnetic field (B0). B0 maps on an axial and a coronal slice of a spherical phantom were obtained at 3T to examine the tip angle and orientation dependence at the 0.001 ppm level. Results: A frequency shift of about 0.3 Hz was observed between tip angles of 10 ° and 90 ° when the thin phantom was normal to B0 at 3T, whereas the shift changed sign and was halved in magnitude when the phantom&apos;s face was parallel to B0. At 9.4T, the effect size increased proportionately. The orientation-dependent frequency shift was also observed in the B0 map experiment. These observations agree with theoretical frequency shift due to longitudinal 1H spin polarization. Conclusion: Magnetic susceptibility contribution from the nuclear paramagnetism should be taken into account in the interpretation of high-precision phase and susceptibility mapping in MRI. Magn Reson Med 77:848–854, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicin-
dc.description.uri1-
dc.language영어-
dc.publisherWILEY-BLACKWELL-
dc.subjectdemagnetization factor-
dc.subjectmagnetic susceptibility-
dc.subjectnuclear paramagnetism-
dc.subjectquantitative susceptibility mapping (QSM)-
dc.titleNuclear paramagnetism-induced MR frequency shift and its implications for MR-based magnetic susceptibility measurement-
dc.typeArticle-
dc.type.rimsART-
dc.identifier.wosid000394544700043-
dc.identifier.scopusid2-s2.0-85010370199-
dc.identifier.rimsid58856ko
dc.date.tcdate2018-10-01-
dc.contributor.affiliatedAuthorJinil Park-
dc.contributor.affiliatedAuthorJeongtaek Lee-
dc.contributor.affiliatedAuthorJang-Yeon Park-
dc.contributor.affiliatedAuthorSeung-Kyun Lee-
dc.identifier.doi10.1002/mrm.26570-
dc.identifier.bibliographicCitationMAGNETIC RESONANCE IN MEDICINE, v.77, no.2, pp.848 - 854-
dc.citation.titleMAGNETIC RESONANCE IN MEDICINE-
dc.citation.volume77-
dc.citation.number2-
dc.citation.startPage848-
dc.citation.endPage854-
dc.date.scptcdate2018-10-01-
dc.description.scptc0-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordPlusMAPPING QSM-
dc.subject.keywordPlusBRAIN-
dc.subject.keywordPlusRESONANCE-
dc.subject.keywordAuthorquantitative susceptibility mapping (QSM)-
dc.subject.keywordAuthornuclear paramagnetism-
dc.subject.keywordAuthormagnetic susceptibility-
dc.subject.keywordAuthordemagnetization factor-
Appears in Collections:
Center for Neuroscience Imaging Research (뇌과학 이미징 연구단) > 1. Journal Papers (저널논문)
Files in This Item:
05_박장연,이승균_Nuclear Paramagnetism-Induced MR Frequency...pdfDownload

qrcode

  • facebook

    twitter

  • Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse