BROWSE

Related Scientist

cnir's photo.

cnir
뇌과학이미징연구단
more info

ITEM VIEW & DOWNLOAD

Insertable Fast-Response Amperometric NO/CO Dual Microsensor: Study of Neurovascular Coupling during Acutely Induced Seizures of Rat Brain Cortex

Cited 17 time in webofscience Cited 16 time in scopus
942 Viewed 217 Downloaded
Title
Insertable Fast-Response Amperometric NO/CO Dual Microsensor: Study of Neurovascular Coupling during Acutely Induced Seizures of Rat Brain Cortex
Author(s)
Yejin Ha; Jeongeun Sim; Youngmi Lee; Minah Suh
Publication Date
2016-03
Journal
ANALYTICAL CHEMISTRY, v.88, no.5, pp.2563 - 2569
Publisher
AMER CHEMICAL SOC
Abstract
This paper reports the fabrication of an insertable amperometric dual microsensor and its application for the simultaneous and fast sensing of NO and CO during acutely induced seizures of living rat brain cortex. NO and CO are important signaling mediators, controlling cerebrovascular tone. The dual NO/CO sensor is prepared based on a dual microelectrode having Au-deposited Pt microdisk (WE1, 76 μm diameter) and Pt black-deposited Pt disk (WE2, 50 μm diameter). The different deposited metals for WE1 and WE2 allow the selective anodic detection of CO at WE1 (+0.2 V vs Ag/AgCl) and that of NO at WE2 (+0.75 V vs Ag/AgCl) with sufficient sensitivity. Fluorinated xerogel coating on this dual electrode provides exclusive selectivity over common biological interferents, along with fast response time. The miniaturized size (end plane diameter < 300 μm) and tapered needle-like sensor geometry make the sensor become insertable into biological tissues. The sensor is applied to simultaneously monitor dynamic changes of NO and CO levels in a living rat brain under acute seizure condition induced by 4-aminopyridine in cortical tissue near the area of seizure induction. In-tissue measurement shows clearly defined patterns of NO/CO changes, directly correlated with observed LFP signal. Current study verifies the feasibility of a newly developed NO/CO dual sensor for real-time fast monitoring of intimately connected NO and CO dynamics. © 2016 American Chemical Society
URI
https://pr.ibs.re.kr/handle/8788114/2543
DOI
10.1021/acs.analchem.5b04288
ISSN
0003-2700
Appears in Collections:
Center for Neuroscience Imaging Research (뇌과학 이미징 연구단) > 1. Journal Papers (저널논문)
Files in This Item:
Insertable Fast-Response Amperometric NO CO Dual Microsensor Study of Neurovascular Coupling During Acutely Induced Seizures of Rat Brain Cortex.pdfDownload

qrcode

  • facebook

    twitter

  • Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse