BROWSE

Related Scientist

cnir's photo.

cnir
뇌과학이미징연구단
more info

ITEM VIEW & DOWNLOAD

A radial sampling strategy for uniform k-space coverage with retrospective respiratory gating in 3D ultrashort-echo-time lung imaging

DC Field Value Language
dc.contributor.authorJinil Park-
dc.contributor.authorTaehoon Shin-
dc.contributor.authorSoon Ho Yoon-
dc.contributor.authorJin Mo Goo-
dc.contributor.authorJang-Yeon Park-
dc.date.available2016-06-22T08:13:32Z-
dc.date.created2016-06-20-
dc.date.issued2016-05-
dc.identifier.issn0952-3480-
dc.identifier.urihttps://pr.ibs.re.kr/handle/8788114/2530-
dc.description.abstractThe purpose of this work was to develop a 3D radial-sampling strategy which maintains uniform k-space sample density after retrospective respiratory gating, and demonstrate its feasibility in free-breathing ultrashort-echo-time lung MRI. A multi-shot, interleaved 3D radial sampling function was designed by segmenting a single-shot trajectory of projection views such that each interleaf samples k-space in an incoherent fashion. An optimal segmentation factor for the interleaved acquisition was derived based on an approximate model of respiratory patterns such that radial interleaves are evenly accepted during the retrospective gating. The optimality of the proposed sampling scheme was tested by numerical simulations and phantom experiments using human respiratory waveforms. Retrospectively, respiratory-gated, free-breathing lung MRI with the proposed sampling strategy was performed in healthy subjects. The simulation yielded the most uniform k-space sample density with the optimal segmentation factor, as evidenced by the smallest standard deviation of the number of neighboring samples as well as minimal side-lobe energy in the point spread function. The optimality of the proposed scheme was also confirmed by minimal image artifacts in phantom images. Human lung images showed that the proposed sampling scheme significantly reduced streak and ring artifacts compared with the conventional retrospective respiratory gating while suppressing motion-related blurring compared with full sampling without respiratory gating. In conclusion, the proposed 3D radial-sampling scheme can effectively suppress the image artifacts due to non-uniform k-space sample density in retrospectively respiratory-gated lung MRI by uniformly distributing gated radial views across the k-space. Copyright (c) 2016 John Wiley & Sons, Ltd-
dc.description.uri1-
dc.language영어-
dc.publisherWILEY-BLACKWELL-
dc.subject3D radial UTE imaging-
dc.subjectlung MRI-
dc.subjectretrospective respiratory gating-
dc.subjectk-space sample uniformity-
dc.titleA radial sampling strategy for uniform k-space coverage with retrospective respiratory gating in 3D ultrashort-echo-time lung imaging-
dc.typeArticle-
dc.type.rimsART-
dc.identifier.wosid000374495900005-
dc.identifier.scopusid2-s2.0-84976217087-
dc.identifier.rimsid55734ko
dc.date.tcdate2018-10-01-
dc.contributor.affiliatedAuthorJinil Park-
dc.contributor.affiliatedAuthorJang-Yeon Park-
dc.identifier.doi10.1002/nbm.3494-
dc.identifier.bibliographicCitationNMR IN BIOMEDICINE, v.29, no.5, pp.576 - 587-
dc.citation.titleNMR IN BIOMEDICINE-
dc.citation.volume29-
dc.citation.number5-
dc.citation.startPage576-
dc.citation.endPage587-
dc.date.scptcdate2018-10-01-
dc.description.wostc5-
dc.description.scptc5-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordPlusNUCLEAR-MAGNETIC-RESONANCE-
dc.subject.keywordPlusMRI-
dc.subject.keywordPlusRECONSTRUCTION-
dc.subject.keywordPlusDESIGN-
dc.subject.keywordPlusMOTION-
dc.subject.keywordPlusTRAJECTORIES-
dc.subject.keywordPlusANGIOGRAPHY-
dc.subject.keywordPlusACQUISITION-
dc.subject.keywordPlusSPIRALS-
dc.subject.keywordAuthor3D radial UTE imaging-
dc.subject.keywordAuthorlung MRI-
dc.subject.keywordAuthorretrospective respiratory gating-
dc.subject.keywordAuthork-space sample uniformity-
Appears in Collections:
Center for Neuroscience Imaging Research (뇌과학 이미징 연구단) > 1. Journal Papers (저널논문)
Files in This Item:
A radial sampling strategy for uniform k-space coverage with retrospective respiratory gating in 3D ultrashort-echo-time lung imaging.pdfDownload

qrcode

  • facebook

    twitter

  • Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse