BROWSE

Related Scientist

cup's photo.

cup
지하실험연구단
more info

ITEM VIEW & DOWNLOAD

Light Channel Signal Analysis with the Lithium Molybdate Crystal R&D Detectors for AMoRE-II Experiments

DC Field Value Language
dc.contributor.authorB. Sharma-
dc.contributor.authorS. C. Kim-
dc.contributor.authorW. T. Kim-
dc.contributor.authorB. Bhandari-
dc.contributor.authorMailyan, B.-
dc.contributor.authorM. B. Kim-
dc.contributor.authorY. D. Kim-
dc.contributor.authorY. H. Kim-
dc.contributor.authorH. J. Lee-
dc.contributor.authorM. H. Lee-
dc.date.accessioned2025-01-20T04:30:10Z-
dc.date.available2025-01-20T04:30:10Z-
dc.date.created2024-12-23-
dc.date.issued2025-01-
dc.identifier.issn0022-2291-
dc.identifier.urihttps://pr.ibs.re.kr/handle/8788114/16201-
dc.description.abstractThis paper presents a comparative study of various light detectors (LDs) developed for different phases of the AMoRE neutrinoless double beta decay experiment. We analyze the performance of these detectors in terms of characteristics such as time response, light collection, and energy resolution. Our primary focus is on evaluating the performance of the AMoRE-II light detector, which is integral to the forthcoming AMoRE-II experiment. It is found that AMoRE-II type LDs outperform other previous light detector types. The best-performing LD exhibits FWHM energy resolution of 99, 198, 198, and 481 eV for baseline and 55Fe X-ray energies of 5.9, 6.5, and 17.5 keV molybdenum X-ray, respectively. We adopted a convolution method to estimate the energy of the scintillation signals from 2.615 MeV gamma rays fully absorbed in a lithium molybdate crystal. The measured energy of scintillation light with AMoRE-II type LDs falls in the range of 2.1-2.5 keV, which corresponds to 0.80-0.96 keV/MeV. This measured energy is approximately 14-39%\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\%$$\end{document} higher than that measured with previous LD types for the experiments.-
dc.language영어-
dc.publisherKluwer Academic/Plenum Publishers-
dc.titleLight Channel Signal Analysis with the Lithium Molybdate Crystal R&D Detectors for AMoRE-II Experiments-
dc.typeArticle-
dc.type.rimsART-
dc.identifier.wosid001376255400001-
dc.identifier.scopusid2-s2.0-85211636858-
dc.identifier.rimsid84749-
dc.contributor.affiliatedAuthorB. Sharma-
dc.contributor.affiliatedAuthorS. C. Kim-
dc.contributor.affiliatedAuthorW. T. Kim-
dc.contributor.affiliatedAuthorB. Bhandari-
dc.contributor.affiliatedAuthorM. B. Kim-
dc.contributor.affiliatedAuthorY. D. Kim-
dc.contributor.affiliatedAuthorY. H. Kim-
dc.contributor.affiliatedAuthorH. J. Lee-
dc.contributor.affiliatedAuthorM. H. Lee-
dc.identifier.doi10.1007/s10909-024-03251-6-
dc.identifier.bibliographicCitationJournal of Low Temperature Physics, v.218, pp.92 - 100-
dc.relation.isPartOfJournal of Low Temperature Physics-
dc.citation.titleJournal of Low Temperature Physics-
dc.citation.volume218-
dc.citation.startPage92-
dc.citation.endPage100-
dc.description.journalClass1-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.relation.journalWebOfScienceCategoryPhysics, Condensed Matter-
dc.subject.keywordAuthorScintillation-
dc.subject.keywordAuthorAMoRE-
dc.subject.keywordAuthorLight detector-
dc.subject.keywordAuthorMolybdate crystals-
dc.subject.keywordAuthorMMC-
Appears in Collections:
Center for Underground Physics(지하실험 연구단) > 1. Journal Papers (저널논문)
Files in This Item:
There are no files associated with this item.

qrcode

  • facebook

    twitter

  • Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse