In situ measurement of relative attenuation length of gadolinium-loaded liquid scintillator using source data at RENO experiment
DC Field | Value | Language |
---|---|---|
dc.contributor.author | H. S. Kim | - |
dc.contributor.author | Kim, S. Y. | - |
dc.contributor.author | Choi, J. H. | - |
dc.contributor.author | Choi, W. Q. | - |
dc.contributor.author | Choi, Y. | - |
dc.contributor.author | Jang, H. I. | - |
dc.contributor.author | Jang, J. S. | - |
dc.contributor.author | Joo, K. K. | - |
dc.contributor.author | Kim, B. R. | - |
dc.contributor.author | Kim, J. Y. | - |
dc.contributor.author | Kim, S. B. | - |
dc.contributor.author | Kim, W. | - |
dc.contributor.author | Kwon, E. | - |
dc.contributor.author | Lee, D. H. | - |
dc.contributor.author | Lim, I. T. | - |
dc.contributor.author | Pac, M. Y. | - |
dc.contributor.author | Park, I. G. | - |
dc.contributor.author | Park, J. S. | - |
dc.contributor.author | Park, R. G. | - |
dc.contributor.author | Seo, H. | - |
dc.contributor.author | Seon Hee Seo | - |
dc.contributor.author | Seon, Y. G. | - |
dc.contributor.author | Shin, C. D. | - |
dc.contributor.author | Yang, J. H. | - |
dc.contributor.author | Yeo, I. S. | - |
dc.contributor.author | Yu, I. | - |
dc.contributor.author | Kim, H. S. | - |
dc.date.accessioned | 2023-11-27T22:02:38Z | - |
dc.date.available | 2023-11-27T22:02:38Z | - |
dc.date.created | 2023-10-23 | - |
dc.date.issued | 2023-07 | - |
dc.identifier.issn | 1748-0221 | - |
dc.identifier.uri | https://pr.ibs.re.kr/handle/8788114/14236 | - |
dc.description.abstract | We present in situ measurements of the relative attenuation length of the gadoliniumloaded liquid scintillator in the RENO (Reactor Experiment Neutrino Oscillation) detectors using radioactive source calibration data. We observed a steady decrease in the attenuation length of the Gd-LS in the RENO detectors by ∼50% in about four years since the commissioning of the detectors. | - |
dc.language | 영어 | - |
dc.publisher | IOP Publishing Ltd | - |
dc.title | In situ measurement of relative attenuation length of gadolinium-loaded liquid scintillator using source data at RENO experiment | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.identifier.wosid | 001071110200001 | - |
dc.identifier.scopusid | 2-s2.0-85165182865 | - |
dc.identifier.rimsid | 81992 | - |
dc.contributor.affiliatedAuthor | Seon Hee Seo | - |
dc.identifier.doi | 10.1088/1748-0221/18/07/P07020 | - |
dc.identifier.bibliographicCitation | JOURNAL OF INSTRUMENTATION, v.18, no.7 | - |
dc.relation.isPartOf | JOURNAL OF INSTRUMENTATION | - |
dc.citation.title | JOURNAL OF INSTRUMENTATION | - |
dc.citation.volume | 18 | - |
dc.citation.number | 7 | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.subject.keywordPlus | LONG-BASE-LINE | - |
dc.subject.keywordAuthor | Liquid detectors | - |
dc.subject.keywordAuthor | Neutrino detectors | - |