Characterization of magnetic field noise in the ARIADNE source mass rotor

DC Field Value Language
dc.contributor.authorAggarwal, Nancy-
dc.contributor.authorSchnabel, A.-
dc.contributor.authorVoigt, J.-
dc.contributor.authorBrown, Alex-
dc.contributor.authorLong, J. C.-
dc.contributor.authorKnappe-Grueneberg, S.-
dc.contributor.authorKilian, W.-
dc.contributor.authorFang, A.-
dc.contributor.authorGeraci, A. A.-
dc.contributor.authorKapitulnik, A.-
dc.contributor.authorDongok Kim-
dc.contributor.authorYounggeun Kim-
dc.contributor.authorLee, I.-
dc.contributor.authorLee, Y. H.-
dc.contributor.authorLiu, C. Y.-
dc.contributor.authorLohmeyer, C.-
dc.contributor.authorReid, A.-
dc.contributor.authorYannis K. Semertzidis-
dc.contributor.authorYun Chang Shin-
dc.contributor.authorShortino, J.-
dc.contributor.authorSmith, E.-
dc.contributor.authorSnow, W. M.-
dc.contributor.authorWeisman, E.-
dc.contributor.authorZhang, H.-
dc.date.accessioned2022-07-29T07:21:37Z-
dc.date.available2022-07-29T07:21:37Z-
dc.date.created2022-02-22-
dc.date.issued2022-02-
dc.identifier.issn2643-1564-
dc.identifier.urihttps://pr.ibs.re.kr/handle/8788114/11989-
dc.description.abstractThe Axion Resonant Interaction Detection Experiment (ARIADNE) is a nuclear-magnetic-resonance-based experiment that will search for novel axion-induced spin-dependent interactions between an unpolarized source mass rotor and spin-polarized He-3 nuclei placed nearby. To detect a feeble axion-mediated signal at the subattotesla level, the experiment relies on ultralow magnetic background and noise. We measure and characterize the magnetic field from a prototype tungsten rotor. We show that the field is dominantly caused by a few discrete magnetic dipoles, likely due to impurities in the rotor. This is done via a numerical optimization pipeline which fits for the locations and magnetic moments of each dipole. We find that under the current demagnetization procedure, the magnetic moment of the impurities is bounded at 10(-9) A m(2). We further show that a shielding factor of 10(9) will support ARIADNE's design sensitivity with the current level of tungsten purity and demagnetization process.-
dc.language영어-
dc.publisherAMER PHYSICAL SOC-
dc.titleCharacterization of magnetic field noise in the ARIADNE source mass rotor-
dc.typeArticle-
dc.type.rimsART-
dc.identifier.scopusid2-s2.0-85125598985-
dc.identifier.rimsid77758-
dc.contributor.affiliatedAuthorDongok Kim-
dc.contributor.affiliatedAuthorYounggeun Kim-
dc.contributor.affiliatedAuthorYannis K. Semertzidis-
dc.contributor.affiliatedAuthorYun Chang Shin-
dc.identifier.doi10.1103/physrevresearch.4.013090-
dc.identifier.bibliographicCitationPhysical Review Research, v.4, no.1-
dc.relation.isPartOfPhysical Review Research-
dc.citation.titlePhysical Review Research-
dc.citation.volume4-
dc.citation.number1-
dc.description.journalClass1-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscopus-
Appears in Collections:
Center for Axion and Precision Physics Research(액시온 및 극한상호작용 연구단) > 1. Journal Papers (저널논문)
Files in This Item:
There are no files associated with this item.

qrcode

  • facebook

    twitter

  • Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse