GEANT4 Simulation of the Shielding of Neutrons from Cf-252 Source
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bak, SI | - |
dc.contributor.author | Park, TS | - |
dc.contributor.author | Hong, SW | - |
dc.contributor.author | Shin, JW | - |
dc.contributor.author | Kevin Insik, Hahn | - |
dc.date.accessioned | 2021-02-24T08:30:02Z | - |
dc.date.accessioned | 2021-02-24T08:30:02Z | - |
dc.date.available | 2021-02-24T08:30:02Z | - |
dc.date.available | 2021-02-24T08:30:02Z | - |
dc.date.created | 2020-11-18 | - |
dc.date.issued | 2011-08 | - |
dc.identifier.issn | 0374-4884 | - |
dc.identifier.uri | https://pr.ibs.re.kr/handle/8788114/9136 | - |
dc.description.abstract | We have done simulation studies of the neutron shielding for a Cf-252 source using GEANT4. For the energy distribution of the neutrons emitted from Cf-252, we have assumed the Watt fission spectrum. The neutron absorption dose rates with and without the shield are estimated for three different materials of Type 304 SS, NS-4-FR and Resin-F. Among various physics models of GEANT4 for the hadronic interactions of low-energy neutrons, we have used the High Precision (HP) model, which is based on the ENDF-VI data and is able to treat elastic, inelastic, fusion and fission processes for neutrons. We have investigated the accuracy of this HP model of GEANT4 by comparing the simulation results with those from MCNP5 and experimental data | - |
dc.publisher | KOREAN PHYSICAL SOC | - |
dc.title | GEANT4 Simulation of the Shielding of Neutrons from Cf-252 Source | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.identifier.wosid | 000294080700151 | - |
dc.identifier.rimsid | 73755 | - |
dc.identifier.doi | 10.3938/jkps.59.2071 | - |
dc.identifier.bibliographicCitation | JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.59, no.2, pp.2071 - 2074 | - |
dc.relation.isPartOf | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
dc.citation.title | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
dc.citation.volume | 59 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 2071 | - |
dc.citation.endPage | 2074 | - |
dc.description.journalClass | 1 | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
dc.subject.keywordAuthor | Neutron shielding | - |
dc.subject.keywordAuthor | Cf-252 | - |
dc.subject.keywordAuthor | GEANT4 | - |
dc.subject.keywordAuthor | Dose rate | - |
dc.subject.keywordAuthor | ENDF-VI | - |