Magnetoresistance in copper at high frequency and high magnetic fields
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Saebyeok Ahn | - |
dc.contributor.author | Sung Woo Youn | - |
dc.contributor.author | Jaeun Yoo | - |
dc.contributor.author | Dong Lak Kim | - |
dc.contributor.author | Junu Jeong | - |
dc.contributor.author | Myung Kyu Ahn | - |
dc.contributor.author | Junsung Kim | - |
dc.contributor.author | D. Lee | - |
dc.contributor.author | Jin Hong Lee | - |
dc.contributor.author | Tea Gyeong Seong | - |
dc.contributor.author | Yannis K. Semertzidis | - |
dc.date.available | 2017-12-19T00:55:06Z | - |
dc.date.created | 2017-12-12 | - |
dc.date.issued | 2017-10 | - |
dc.identifier.issn | 1748-0221 | - |
dc.identifier.uri | https://pr.ibs.re.kr/handle/8788114/4073 | - |
dc.description.abstract | In halo dark matter axion search experiments, cylindrical microwave cavities are typically employed to detect signals from the axion-photon conversion. To enhance the conversion power and reduce the noise level, cavities are placed in strong solenoid magnetic fields at sufficiently low temperatures. Exploring high mass regions in cavity-based axion search experiments requires high frequency microwave cavities and thus understanding cavity properties at high frequencies in extreme conditions is deemed necessary. We present a study of the magnetoresistance of copper using a cavity with a resonant frequency of 12.9 GHz at the liquid helium temperature in magnetic fields up to 15 T utilizing a second generation high temperature superconducting magnet. The observations are interpreted to be consistent with the anomalous skin effect and size effect. This is the first measurement of magnetoresistance at a high frequency (>10 GHz) in high magnetic fields (>10 T). © 2017 IOP Publishing Ltd and Sissa Medialab | - |
dc.description.uri | 1 | - |
dc.language | 영어 | - |
dc.publisher | IOP PUBLISHING LTD | - |
dc.subject | Dark Matter detectors (WIMPs, axions, etc.) | - |
dc.subject | Detector design and construction technologies and materials | - |
dc.subject | Microwave radiometers | - |
dc.title | Magnetoresistance in copper at high frequency and high magnetic fields | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.identifier.wosid | 000414167100023 | - |
dc.identifier.scopusid | 2-s2.0-85033776974 | - |
dc.identifier.rimsid | 61697 | ko |
dc.date.tcdate | 2018-10-01 | - |
dc.contributor.affiliatedAuthor | Sung Woo Youn | - |
dc.contributor.affiliatedAuthor | Jaeun Yoo | - |
dc.contributor.affiliatedAuthor | Junu Jeong | - |
dc.contributor.affiliatedAuthor | Junsung Kim | - |
dc.contributor.affiliatedAuthor | D. Lee | - |
dc.contributor.affiliatedAuthor | Yannis K. Semertzidis | - |
dc.identifier.doi | 10.1088/1748-0221/12/10/P10023 | - |
dc.identifier.bibliographicCitation | JOURNAL OF INSTRUMENTATION, v.12, no.10, pp.P10023 | - |
dc.citation.title | JOURNAL OF INSTRUMENTATION | - |
dc.citation.volume | 12 | - |
dc.citation.number | 10 | - |
dc.citation.startPage | P10023 | - |
dc.date.scptcdate | 2018-10-01 | - |
dc.description.wostc | 2 | - |
dc.description.scptc | 2 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordAuthor | Dark Matter detectors (WIMPs, axions, etc.) | - |
dc.subject.keywordAuthor | Detector design and construction technologies and materials | - |
dc.subject.keywordAuthor | Microwave radiometers | - |